# Model 526 Changelog

NOTE, when updating between versions where any digit but the last has changed:
- New settings have been added
- The update will set reset the unit to Factory Default settings, except for IP settings
- Previous settings will automatically be recalled after Factory Defaults are loaded
- This will take ~30 seconds after the unit has been updated, and it will reboot after
- Any new settings that didn't exist in the previous firmware will be at their respective defaults

How to update firmware:
- Access the Admin webpage
- Click "Select Firmware File..."
- Select the firmware (.bin file)
- Click "Update Firmware"
- Wait for update to complete

## [1.0.0.12] - 2026-09-17

### Fixed
- Fixed the GPO not following the alarm states after the first rotation when using StationRotation.

## [1.0.0.11] - 2026-06-18

### Fixed
- Fix Now Playing webpage tuning to 1700 when frequency is 1710 on load

## [1.0.0.10] - 2025-08-12

### Fixed
- Fixed IF and audio bandwidth not using the saved values on boot
- This update should address some occurrences of the display becoming "glitchy"

## [1.0.0.9] - 2025-03-19

### Fixed
- Fixed issues related to the handling of audio muting, where the mute state might not be correct
  depending on the state of the day/night low signal alarms, the day/night mute action, etc.
- Allow Dante gateway and DNS to be set to 0.0.0.0

## [1.0.0.8] - 2024-11-13

### Fixed
- Fixed AES output channel status CRC being incorrect (does not affect audio)

## [1.0.0.7] - 2024-11-06

### Fixed
- SNMP OID currentPreset was off by 1 when setting/getting
- Consistent audio metering below -40dB (between 541/551/552/526)

## [1.0.0.6] - 2024-06-26

### Fixed
- Fixed an issue where the DSP could lock up, leaving metering, etc. not working

## [1.0.0.5] - 2024-05-07

### Fixed
- Fixed/tweaked a bit of inaccuracy in the modulation readings and MDCL measurement

## [1.0.0.4] - 2024-04-30

### Fixed
- Fixed the web audio stream not working anymore after latest iOS update